Parameter
|
Motor
Size
|
Values
|
|
Intensification
Pressure
|
Fractional
|
400
– 600 bar
|
|
>1
kW
|
750
– 920 bar
|
|
Solidification
Range
|
All
|
12
– 18 seconds
|
Table 11.3.1: Values of intensification pressures and solidification times used to die-cast copper rotors
Experience with the smaller rotors showed that high values of intensification pressure could actually deform the lamination slots, leading to increases in stray load losses and difficulty with assembly. Therefore, lower intensification pressures were used with the smaller rotors.