Most of the prototype copper rotors die-cast during the ICA/CDA project were produced using intensification pressures and solidification times in the ranges listed in Table 11.3.1.

Parameter

Motor Size

Values

Intensification Pressure

Fractional

400 – 600 bar

>1 kW

750 – 920 bar

Solidification Range

All

12 – 18 seconds



Table 11.3.1: Values of intensification pressures and solidification times used to die-cast copper rotors

Experience with the smaller rotors showed that high values of intensification pressure could actually deform the lamination slots, leading to increases in stray load losses and difficulty with assembly. Therefore, lower intensification pressures were used with the smaller rotors.